Journal of Civil Aviation University of China ›› 2019, Vol. 37 ›› Issue (3): 60-64.

• Engineering and Technology • Previous Articles    

Carbon fiber fracture recognition based on electrical resistance method#br#

LU Xiang, ZHAO Zhenyao, LIN Yueguo, JIA Baohui#br#   

  1. (College of Aeronautical Engineering, CAUC, Tianjin 300300, China)
  • Online:2019-06-27 Published:2020-04-01

Abstract: Electrical resistance method is used to identify the internal fiber fracture of CFRP under tension. A preliminary theoretical exploration is carried out to realize on-line health monitoring on aircraft composite structure. Energized tension test and finite element simulation are conducted aiming at the unidirectional laminate [0]8 of T800 carbon fiber. It is proven that the electrical resistance method can soundly reflect fiber fracture. The judging standard of T800 fiber fracture by electrical resistance method is given: before resistance changing rate ΔR/R0 reaches 0.25, only fiber elastically deformation occurs; when ΔR/R0 reaches 0.25, fiber breaks; when ΔR/R0 reaches 3.5, the serious fiber damage occurs.

Key words: carbon fiber, composite, electrical method, finite element analysis

CLC Number: