• Engineering and Technology • Previous Articles     Next Articles

Microstructure of TC4 welded joint damaged by foreign object

JI Zhaohui, XU Dongcheng, JIA Peng   

  1. (Civil Aircraft Airworthiness and Maintenance Key Lab of Tianjin, CAUC, Tianjin 300300, China)
  • Received:2016-03-10 Revised:2016-04-13 Online:2016-12-26 Published:2016-12-28

Abstract:

FOD (foreign object damage)simulation ofaircraft engine compressorbladesis conducted bydrop hammermethod on TC4 welded joint with micro plasma arc welding, studying the micro structure, depth and width of FOD. Results show that the depth and width of FOD increase linearly with the impact absorbing energy. Given the same impact absorbing energy, the size of FOD reaches its maximum at surfacing layer, then at HAZ(heat affected zone), and
minimum at base-metal. The damage form generated by drop hammer method includes surface cracks, subsurface plastic deformation, subsurface microvoid, subsurface cracks and adiabatic shear zones. Given 4 ~8 J impact absorbing energy, microvoid appeares at the base titanium alloy metal, HAZ as well as surfacing layer, and is developed into cracks under the action of shear forces at HAZ and adiabatic shear zones.

Key words: foreign object damage, TC4 titanium alloy, welded joint, micro plasma arc welding, microstructure

CLC Number: